Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Radiol. bras ; 55(5): 305-311, Sept.-Oct. 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1406518

RESUMO

Abstract The analysis of body composition is a fundamental part of a nutritional status assessment, and the use of diagnostic imaging methods has been increasingly required for an adequate characterization of the lean body mass and fat mass. Body composition measurements are useful in evaluating the effectiveness of nutritional interventions and monitoring changes associated with aging and chronic diseases. Whole-body densitometry using dual-energy X-ray absorptiometry (DEXA) is one of the most widely used methods in clinical practice, allowing highly accurate assessment of the bone mineral content, lean body mass, and fat mass. Although a DEXA examination provides a lot of information, there is still no universal standardization of the parameters to be included in radiology reports. The aim of this study was to review the most relevant information for assessing body composition by whole-body densitometry.


Resumo A análise da composição corporal é parte fundamental de uma avaliação nutricional, em que a utilização de métodos diagnósticos por imagem tem sido cada vez mais requisitada para uma adequada caracterização da massa magra e massa gorda corporal. Medidas de composição corporal são úteis em avaliar a eficácia das intervenções nutricionais e monitorar as mudanças associadas ao envelhecimento e condições de doenças crônicas. A densitometria de corpo inteiro utilizando a técnica de absorciometria de dupla energia (DEXA) é um dos métodos mais utilizados na prática clínica, que permite avaliação com elevada acurácia do conteúdo mineral ósseo, da gordura corporal e da massa magra. Este exame fornece grande quantidade de informações, no entanto, ainda não existe uma padronização universal de quais parâmetros devem ser incluídos nos relatórios radiológicos. O objetivo deste trabalho é revisar as informações mais relevantes para avaliação da composição corporal fornecidas pela densitometria de corpo inteiro.

2.
Medicina (Ribeirao Preto, Online) ; 55(1)maio 2022. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1402666

RESUMO

Background: Spontaneous Bacterial Peritonitis (SBP) is a serious and frequent complication among cirrhotic patients with ascites and can be diagnosed by cytological analysis of the ascitic fluid. The microbiological culture of ascitic fluid, however, is positive in less than 40% of SBP cases, which often results in inappropriate antimicrobial therapy. Empirical therapy may be suboptimal, increasing patient's risk of aggravation, or overestimated, unnecessarily boosting bacterial resistance. Objective: This experimental laboratory study aimed to standardize and verify the technical feasibility of ascitic fluid vacuum filtration, as a way to optimize the etiological diagnosis of SBP, compared to the automated method. Method: The method evaluated and standardized in this study was ascitic fluid vacuum filtration. Its principle is the concentration of bacteria on a filter membrane. Results: This study included 36 cirrhotic patients treated at a public university hospital between 11.13.2017 and 06.30.2019. Among them, 47.2% (17/36) presented cytology test results compatible with SBP. For these patients, culture sensitivity using the automated method was 35.3% (6/17), against 11.8% (2/17) with the vacuum filtration method. Conclusion: In conclusion, vacuum filtration does not improve the microbiological diagnosis of SBP in this population compared to the automated method (AU)


Contexto: A Peritonite Bacteriana Espontânea (PBE) é uma complicação grave e frequente entre pacientes cirróticos com ascite, diagnosticada por meio da análise citológica do líquido ascítico. A cultura microbiológica do líquido ascítico, por sua vez, é positiva em menos de 40% dos casos de PBE, o que resulta frequentemente na instituição de terapia antimicrobiana inapropriada. A terapia empírica pode ser subótima, aumentando o risco de agravamento do paciente, ou superestimada, impulsionando desnecessariamente a resistência bacteriana. Objetivo: Estudo experimental laboratorial, propôs padronizar e verificar a viabilidade técnica da filtração a vácuo do líquido ascítico, como forma de otimizar o diagnóstico etiológico na PBE, comparativamente ao sistema automatizado de culturas de sangue. Método: O método avaliado e padronizado neste estudo foi a da filtragem a vácuo do líquido ascítico. Esse tem como princípio a concentração da bactéria em uma membrana filtrante. Resultados: Nesse estudo, foram incluídos 36 pacientes cirróticos atendidos em um hospital público universitário, entre 13.11.2017 e 30.06.2019. Entre eles, 47,2% (17/36) apresentaram citologia compatível com PBE. Nesses, a sensibilidade da cultura pelo método semi-automatizado foi de 35,3% (6/17) e da cultura pelo método da filtragem a vácuo foi de 11,8% (2/17). Conclusão: Em conclusão, a filtragem a vácuo não melhora o diagnóstico microbiológico da PBE em relação ao método automatizado (AU)


Assuntos
Humanos , Peritonite , Técnicas de Laboratório Clínico , Cirrose Hepática , Microbiologia
3.
Artigo em Inglês | LILACS | ID: biblio-1368242

RESUMO

ABSTRAC: Background: Spontaneous Bacterial Peritonitis (SBP) is a serious and frequent complication among cirrhotic patients with ascites and can be diagnosed by cytological analysis of the ascitic fluid. The microbiological culture of ascitic fluid, however, is positive in less than 40% of SBP cases, which often results in inappropriate antimicrobial therapy. Empirical therapy may be suboptimal, increasing patient's risk of aggravation, or overestimated, unnecessarily boosting bacterial resistance. Objective: This experimental laboratory study aimed to standardize and verify the technical feasibility of ascitic fluid vacuum filtration, as a way to optimize the etiological diagnosis of SBP, compared to the automated method. Method: The method evaluated and standardized in this study was ascitic fluid vacuum filtration. Its principle is the concentration of bacteria on a filter membrane. Results: This study included 36 cirrhotic patients treated at a public university hospital between 11.13.2017 and 06.30.2019. Among them, 47.2% (17/36) presented cytology test results compatible with SBP. For these patients, culture sensitivity using the automated method was 35.3% (6/17), against 11.8% (2/17) with the vacuum filtration method. Conclusion: In conclusion, vacuum filtration does not improve the microbiological diagnosis of SBP in this population compared to the automated method. (AU)


RESUMO:Contexto: A Peritonite Bacteriana Espontânea (PBE) é uma complicação grave e frequente entre pacientes cirróticos com ascite, diagnosticada por meio da análise citológica do líquido ascítico. A cultura microbiológica do líquido ascítico, por sua vez, é positiva em menos de 40% dos casos de PBE, o que resulta frequentemente na instituição de terapia antimicrobiana inapropriada. A terapia empírica pode ser subótima, aumentando o risco de agravamento do paciente, ou superestimada, impulsionando desnecessariamente a resistência bacteriana. Objetivo: Estudo experimental laboratorial, propôs padronizar e verificar a viabilidade técnica da filtração a vácuo do líquido ascítico, como forma de otimizar o diagnóstico etiológico na PBE, comparativamente ao sistema automatizado de culturas de sangue. Método: O método avaliado e padronizado neste estudo foi a da filtragem a vácuo do líquido ascítico. Esse tem como princípio a concentração da bactéria em uma membrana filtrante. Resultados: Nesse estudo, foram incluídos 36 pacientes cirróticos atendidos em um hospital público universitário, entre 13.11.2017 e 30.06.2019. Entre eles, 47,2% (17/36) apresentaram citologia compatível com PBE. Nesses, a sensibilidade da cultura pelo método semi-automatizado foi de 35,3% (6/17) e da cultura pelo método da filtragem a vácuo foi de 11,8% (2/17). Conclusão: Em conclusão, a filtragem a vácuo não melhora o diagnóstico microbiológico da PBE em relação ao método automatizado. (AU)


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Peritonite , Líquido Ascítico , Técnicas de Laboratório Clínico , Cirrose Hepática , Microbiologia
4.
Arq. bras. neurocir ; 40(4): 333-338, 26/11/2021. tab
Artigo em Inglês | LILACS | ID: biblio-1362075

RESUMO

Obsessive-compulsive disorder (OCD), a disabling chronic neuropsychiatric disease, entails high economic costs to society and has high morbidity and mortality rates. The first-line treatments for OCD are selective serotonin reuptake inhibitors and cognitivebehavioral therapy. However, this disorder has the highest refractory index to noninvasive treatment. Alternatively, ablative thermocoagulation neurosurgical techniques have shown efficacy and few adverse effects. The present systematic review aimed to identify validated protocols to observe the effectiveness of ablative procedures in the treatment of severe and refractory OCD, as well as their possible adverse effects and benefits. This review supports the effectiveness of ablative methods by presenting them as a safe non-experimental therapeutic option for cases of highlyrefractory OCD. Additional relevant findings were the improvement in cognitive function, functional capacity, affective orientation, and quality of life, which contribute to the destigmatization of this surgical technique. Further controlled studies may lead to the individualization of recommendations of targets for ablative thermocoagulation.


Assuntos
Eletrocoagulação/psicologia , Transtorno Obsessivo-Compulsivo/fisiopatologia , Transtorno Obsessivo-Compulsivo/terapia , Psicocirurgia/métodos , Eletrocoagulação/métodos , Transtorno Obsessivo-Compulsivo/diagnóstico
5.
Ciênc. agrotec., (Impr.) ; 41(4): 378-389, July-Aug. 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-890636

RESUMO

ABSTRACT The distribution of externally studentized midrange was created based on the original studentization procedures of Student and was inspired in the distribution of the externally studentized range. The large use of the externally studentized range in multiple comparisons was also a motivation for developing this new distribution. This work aimed to derive analytic equations to distribution of the externally studentized midrange, obtaining the cumulative distribution, probability density and quantile functions and generating random values. This is a new distribution that the authors could not find any report in the literature. A second objective was to build an R package for obtaining numerically the probability density, cumulative distribution and quantile functions and make it available to the scientific community. The algorithms were proposed and implemented using Gauss-Legendre quadrature and the Newton-Raphson method in R software, resulting in the SMR package, available for download in the CRAN site. The implemented routines showed high accuracy proved by using Monte Carlo simulations and by comparing results with different number of quadrature points. Regarding to the precision to obtain the quantiles for cases where the degrees of freedom are close to 1 and the percentiles are close to 100%, it is recommended to use more than 64 quadrature points.


RESUMO A distribuição da midrange estudentizada externamente foi criada com base nos procedimentos de estudentização de Student e foi inspirada na distribuição da amplitude estudentizada externamente. O amplo uso da amplitude estudentizada externamente em comparações múltiplas também foi uma das motivações para desenvolver esta nova distribuição. Neste trabalho objetivou-se derivar expressões analíticas da distribuição da midrange estudentizada externamente, obtendo a função de distribuição, função densidade de probabilidade, função quantil e geradores de números aleatórios. Essa é uma nova distribuição que os não há relatos na literatura especializada. Um segundo objetivo foi construir um pacote R para obter numericamente as funções mencionadas e torná-las disponíveis para a comunidade científica. Os algoritmos foram propostos e implementados usando os métodos de quadratura Gauss-Legendre e Newton-Raphson no software R, resultando no pacote SMR, disponível para baixar na página do CRAN. As rotinas implementadas apresentaram alta acurácia, sendo verificadas usando simulação Monte Carlo e pela comparação com diferentes pontos de quadratura. Quanto a precisão para se obter os quantis da distribuição da midrange estudentizada externamente para 1 grau de liberdade ou percentis próximo de 100%, é sugerido utilizar mais do que 64 pontos de quadratura.

6.
Asian Pacific Journal of Tropical Biomedicine ; (12): 716-719, 2013.
Artigo em Chinês | WPRIM | ID: wpr-672730

RESUMO

Objective:To determine the effects of high voltage electrical stimulation (HVES, 800 Voltage) on rapid decreases in pH values and improvements in meat quality. Methods:A total of 50 beef carcasses were applied, divided into two groups, one as a control and another for HVES. Meat quality was evaluated based on M. longissimus dorsi by examining pH and temperature levels at 1, 2, 5, 10 and 24 h, while color stability was examined seven days after slaughter. Results:HVES decreased the pH values of the meat and accelerated rigor mortis (P Conclusion:the HVES had positive effects on meat quality and color stability, in contrast to undesirable consumer preferences.

7.
Ciênc. rural ; 42(2): 354-359, fev. 2012. ilus, tab
Artigo em Português | LILACS | ID: lil-618102

RESUMO

Dentro do contexto nutricional, a suplementação de microminerais em rações para aves frequentemente é feita em quantidades superiores às exigidas na tentativa de assegurar o bom desempenho dos animais. Os experimentos do tipo dose resposta são muito comuns na determinação de níveis ótimos dos nutrientes na ração e contemplam a utilização de modelos de regressão para atingir tal objetivo. Porém, na análise de regressão usual, geralmente, não se usa uma informação a priori sobre uma possível relação de ordem na variável resposta. A regressão isotônica é um método de estimação por mínimos quadrados que gera estimativas que satisfazem a mesma ordenação dos dados. Na teoria da regressão isotônica, essa informação é utilizada de forma essencial e espera-se que a eficiência do ajuste seja aumentada quando se faz uso dela. Diante do exposto, o presente trabalho tem como objetivo utilizar uma metodologia de regressão isotônica, como uma forma alternativa para analisar dados de deposição de zinco (Zn) na tíbia de aves machos da linhagem Hubbard. No estudo, foram considerados os modelos de platô de resposta polinomial quadrático e não linear exponencial. Além desses modelos, também foi proposto o ajuste de um modelo logarítmico para os dados e a eficiência da metodologia foi avaliada por meio de um estudo de simulação Monte Carlo, considerando diferentes cenários para os valores paramétricos. A isotonização dos dados propiciou uma melhora em todos os avaliadores de qualidade de ajuste considerados no trabalho. Dentre os modelos utilizados, o logarítmico apresentou estimativas dos parâmetros mais coerentes com os valores relatados na literatura, para os dados de deposição de Zn na tíbia de aves machos.


Within the nutritional context, the supplementation of microminerals in bird food is often made in quantities exceeding those required in the attempt to ensure the proper performance of the animals. The experiments of type dosage x response are very common in the determination of levels of nutrients in optimal food balance and include the use of regression models to achieve this objective. Nevertheless, the regression analysis routine, generally, uses a priori information about a possible relationship between the response variable. The isotonic regression is a method of estimation by least squares that generates estimates which preserves data ordering. In the theory of isotonic regression this information is essential and it is expected to increase fitting efficiency. The objective of this work was to use an isotonic regression methodology, as an alternative way of analyzing data of Zn deposition in tibia of male birds of Hubbard lineage. We considered the models of plateau response of polynomial quadratic and linear exponential forms. In addition to these models, we also proposed the fitting of a logarithmic model to the data and the efficiency of the methodology was evaluated by Monte Carlo simulations, considering different scenarios for the parametric values. The isotonization of the data yielded an improvement in all the fitting quality parameters evaluated. Among the models used, the logarithmic presented estimates of the parameters more consistent with the values reported in literature.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA